49 CFR § 177.835 & MSHA PART 56 / 57 BULK EXPLOSIVES SAFETY

Bulk ANFO & Emulsion Blasting Transload Manual

Standard operating procedures for bulk emulsion road tankers (NA0331 / UN0332), progressive cavity stator thermal protection, hydraulic auger delivery, and mine-site digital ticketing.

01 Bulk Cargo & Pumping Skid Configuration

02 Transfer Telemetry & Pump Health

Pump Friction Thermal Safety
NORMAL (135°F < 180°F LIMIT)
Safe
Estimated Pumping Duration
41.5 Minutes
1,085 lbs/min
Pump Deadhead & Overpressure Interlock
DISCHARGE LINE CLEAR (65 PSIG)
Pressure relief bypass set at 125 PSIG prevents confined hydraulic detonation risks.
MSHA Delivery Ticket & Inventory Sync
AUTOMATED eBOL SIGNED & SYNCED
Exspeedite TMS logs exact net gallons delivered directly to mine silo telemetry.
Conforms to IME Safety Library Publication No. 17 (Guidelines for Bulk Transportation) and MSHA 30 CFR § 56.6200.
01

Run-Dry Thermal Protection

Progressive cavity pumps rely on emulsion for lubrication. If run dry, stator friction heats the elastomer rapidly. If internal temps cross 190°F (88°C), trapped ammonium nitrate can decompose. Automatic thermistor probes shut down the PTO if temps exceed 180°F.

02

Deadhead Pressure Relief

Pumping against a closed valve causes hydraulic shock and rapid energy input into the matrix. Pumping skids must incorporate spring-loaded rupture discs or hydraulic bypass loops discharging back into the tanker dome to prevent confinement overpressure.

03

Mine-Site Delivery Automation

Exspeedite mobile app captures Coriolis flow meter totalizers, gross/tare scale tickets, and MSHA mine representative electronic signatures on the driver tablet, invoicing the customer in under 60 seconds.