GIGAJOULE STORED ENERGY • QUENCH PRESSURE DISCHARGE • 5-GAUSS EXCLUSION BOUNDARY • DUCT SIZING

Terawatt SMES High-Current Quench Pressure Relief & Stray Field Calculator

Model stored magnetic energy, rapid helium vaporization mass flow, emergency burst duct cross-sectional area, and public exclusion boundaries during commissioning or factory testing.

Stored Energy Range
10 to 250 GJ
Gigajoule magnetic field
Quench Peak Temp
≤ 180 Kelvin
HTS thermal runaway ceiling
Public Safe Perimeter
≤ 5.0 Gauss
Pacemaker interference limit
Relief Valve Code
CGA S-1.3 & ASME
Cryogenic burst disc standard

01 SMES Gigajoule Quench Dynamics & Stray Field Simulator

Simulate stored magnetic energy dissipation, cryogenic helium vaporization rates, and required emergency vent duct diameter.

Coil Stored Energy (GJ) 50 Gigajoules
Operating Current (kA) 40 kA
Helium Inventory (Liters) 35,000 Liters
Quench Dump Time (s) 5.0 Seconds
Boil-Off Mass Flow
480 kg/sec
Peak helium gas surge
Min Vent Duct Diameter
24.0 Inches
ASME burst disc sizing
5-Gauss Exclusion Radius
42.5 Meters
Active field boundary
Quench Relief Margin
NOMINAL • OVERPRESSURE RELIEF ADEQUATE
Vent Exhaust Velocity
148 m/s (Sub-Sonic)

02 Quench Protection Heaters, Active Dump Resistors & 5-Gauss Perimeter

When a multi-gigajoule SMES magnet experiences a quench (a localized transition from superconducting to normal resistive state), the stored electromagnetic energy (\(E = \frac{1}{2} L I^2\)) must be dissipated within seconds. Fast-acting quench protection heaters drive the entire coil normal to distribute heat uniformly, while counter-wound energy extraction dump resistors absorb up to 85% of the electrical energy externally.

Burst Disc Overpressure

Reverse-buckling graphite or stainless burst discs rupture at 4.0 bar differential pressure, directing cold gaseous helium into vertical diffuser towers.

5-Gauss Public Perimeter

The 5-Gauss magnetic line must be marked with interlocked optical barriers during energization to prevent pacemakers or ferromagnetic items from entering.

Cold Mass Thermal Shock

Internal coil winding temperatures are mapped via fiber-optic distributed temperature sensors (DTS) to verify zero localized hot-spots above 200 K.

03 SMES Factory Testing & Field Transit Checklist

✓
ASME Burst Disc Certificate: Certified ASME Section VIII burst disc with lot test rupture report logged in Exspeedite.
✓
Quench Vent Exhaust Trajectory: Computational fluid dynamics study confirms cold helium cloud disperses clear of building air intakes.
✓
Magnetic Shield Attenuation: Low-carbon steel shielding plates reduce stray dipole field below 5 Gauss at facility perimeter fence.
✓
Exspeedite Specialized Power Equipment Dispatch: Direct dispatch integration for heavy schnabel rail carriers and cryogenic hazmat drivers.

Manage High-Current Superconducting Logistics in Exspeedite TMS

Unify cryogenic pressure relief calculations, magnetic safety boundaries, heavy schnabel rail shipments, and grid substation receiving in one unified cockpit.