ISO 14644-1 CLASS 5 / CLASS 7 AIRBORNE PARTICULATE ENGINEERING

Cleanroom Van HEPA Filtration & Particle Calculator

Interactive airflow engineering tool for aerospace satellites, optical payloads, and EUV semiconductor scanners: positive pressure differentials, air changes per hour (ACH), and real-time optical particle counting.

01 Cleanroom Enclosure & Filtration Setup

Enclosure Particle Dynamics & Airflow Telemetry

REAL-TIME MODEL
Air Changes / Hr
50.5 ACH
Class 5 target: > 45
Est. 0.5 µm Count
820 / m³
Class 5 cap: 3,520
Differential Delta
20.0 Pa
Min: 12.5 Pa (+0.05")
Particulate Margin to ISO Threshold: 76.7% Clean Margin
Overall Airflow Rating: OPTIMAL LAMINAR PURGE
Secondary Containment: Airlock Vestibule Armed
Compliant with ISO 14644-1:2015 and IEST-RP-CC006.3 cleanroom air testing standards.

Cleanroom Trailer Engineering & Airborne Particulate Infiltration Defense

Positive Pressure Seals

By maintaining static pressure at or above +0.05 inches water gauge (12.5 Pa), any door seam or cable feedthrough breach forces clean air outward, blocking road grit, diesel soot, and dust from entering.

Laminar Air Distribution

Air is passed through ceiling-mounted HEPA fan filter units (FFUs) down over the payload at uniform velocities (70 - 90 FPM), carrying stray particles down into low-wall return plenums.

Optical Telemetry Streaming

Laser diode particle counters continuously sample air at 0.1 CFM, logging 0.3 µm and 0.5 µm counts directly into Exspeedite TMS to provide an unalterable chain-of-cleanliness certificate.

ISO 14644-1 Class Max 0.1 µm / m³ Max 0.3 µm / m³ Max 0.5 µm / m³ Max 5.0 µm / m³
ISO Class 5 100,000 10,200 3,520 29
ISO Class 6 1,000,000 102,000 35,200 293
ISO Class 7 N/A N/A 352,000 2,930
ISO Class 8 N/A N/A 3,520,000 29,300